Internal chamber, double wall and doors comply with the ASME code, and are completely made of type 316 L stainless steel. The inner surfaces in contact with steam are sanitary polished. The chamber is thermally insulated.
 
 
 
 
Depending on the model, sliding doors can be vertical or horizontal. They close airtight by means of a pressurized silicone seal inserted in the autoclave.
Sterilizers can be single or double door. Double door equipment is fitted with safety systems which prevent both doors from opening simultaneously.
   
 
The equipment is fitted with a microprocessed control with a Touch Screen panel. It can store 99 cycles completely programmable by means of a password, ensuring absolute security in the operation.
It has a parallel alarm program which verifies the process parameters.
   
 
Before starting a cycle, the operator may enter the data of the product to be sterilized so that they are printed in the cycle graphic record, enabling the correct traceability of the product.
     
Sterilizers are manufactured to work with central steam. When there is no steam available, the equipment can be provided with its own steam generator.
 
An alphanumerical printer records all cycle stages and variables. All the information needed to ensure the correct fulfillment of the cycle parameters is recorded.
     



 
Loading system consisting of internal and external carts for loading and carrying the materials to be sterilized in the autoclave.
The internal cart is made of type 316 stainless steel with lateral runners for carrying materials, adjustable in height, and lower wheels made of type 316 stainless steel. The external cart is made of type 304 stainless steel, with four tyred wheels, two fixed and two spinning. It is fitted with upper rails made of 304 stainless steel with leveling and fixing screws.

Special equipment with chamber capacity for more than 20.000 liters available upon request.

Documentation: Before delivery, our equipment is properly certified in our plant performing the corresponding Factory Acceptance Test (F.A.T). Once installed, the Site Acceptance Test (S.A.T) is performed.

Thermal Profiles: All instruments used are traceable to primary patterns to measure the temperature of a process, or to verify control or measuring instruments.

 